Free tools for electricians

No sign-up, right in your browser

PV Peak Power
Daily curve and peak power of your PV system – per inverter and module field, with SVG chart.
Solar position model
Input Inverters, modules, tilt, orientation
Output DC/AC peak, daily curve chart
Location 50,11° N – 21 June
Voltage Drop
Is the cross-section enough for the length? ΔU in volts and percent, with calculation steps and the next suitable cross-section.
DIN 18015-1 · 3 %
Input Supply, length, current or power, cross-section, conductor
Output ΔU, Δu, traffic light, minimum cross-section, maximum length
Modbus Register Calculator
Convert registers to float32, int16, uint32 and more – with word order, scaling and address help.
Modbus · IEEE 754
Input 1–4 registers, hex or decimal
Output All interpretations, steps, address ↔ offset
RCD & Wallbox Check
Register the wallbox or get grid operator consent? Plus the matching RCD type A, F or B – with reasoning.
NAV § 19 · § 14a EnWG · VDE 0100-722
Input Charge points, power, existing wallboxes
Output Registration or consent, § 14a, RCD type
Printable Checklists
System documentation, initial verification with test sheet, DGUV V3, alterations and surge protection – tick off or print as A4 PDF.
A4 · tick-off
Content Five checklists
Output Print or PDF, A4 portrait
Cable Cross-Section
Cross-section by all four criteria: current capacity, overload, disconnection, voltage drop. You can already calculate the voltage drop.
Coming Soon
Status Voltage drop available, cross-section planned

PV Calculator in Three Steps

Free and without sign-up – right in the browser.

Add inverters

Name and rated AC power per inverter.

Assign module fields

Per field module power, count, tilt and orientation – several fields per inverter, e.g. east and west.

Read the result

DC and AC peak per inverter, overall result and the daily curve as a chart.

Good to Know

  • Why 21 June? On the day with the highest sun position you see the peak that inverters and cables have to handle.
  • East-west instead of south: two fields on one inverter give a wider, flatter curve – the peak is well below the sum of the module power.
  • Orientation in degrees: 90° east, 180° south, 270° west.
  • System efficiency: losses from cables, temperature and soiling are combined into one value.
Example: hall roof Input
Inverter
WR-01 · 50 kW AC
East field
70 × 430 Wp · 10° tilt · 90°
West field
70 × 430 Wp · 10° tilt · 270°
Installed
60,2 kWp DC
Try it with your own values Open calculator →

Template Library

Stop retyping cables and devices: pick the type and the values are there. Add your own templates for your group.

Over 30 cable types

with cores, cross-section, outer diameter, weight and bend radius

NYM-J 3x1,5NYM-J 5x2,5NYY-J 5x10NAYY-J 4x150 SE H07RN-F 5G2,5H1Z2Z2-K 1x6Cat.7 S/FTPJ-Y(ST)Y 2x2x0,8 LiYCY 4x0,5Li2YCY (TP) 2x2x0,5Fibre OS2

Over 25 devices

with manufacturer, model and connection sockets

SMA Sunny TripowerHuawei SUN2000Fronius TauroSungrow SG125CX Sungrow PowerStackSMA Data Manager MSolar-Log Base Janitza UMG 96RM-ETeltonika RUT241

Excel templates: cable list and circuit list

Free download – no sign-up, no email. Designations stay text, installation method and status come from a drop-down. The templates are in German.

Cable list

  • Designation, from, to, cable type, cores × cross-section, length
  • Installation method A1–G and status as drop-down
  • Example sheet from an office building, prints on A4 landscape

Excel file (.xlsx) · 11 KB

Circuit list

  • Device tag, circuit, protective device, phase, RCD, cable, target
  • Empty columns for test results: R_iso, Zs or Ik, IΔn, tA
  • Example sheet from an office building, prints on A4 landscape

Excel file (.xlsx) · 12 KB

In CircuitDoc the lists build themselves

Enter devices and cables once – cable list, circuit list, pull list and circuit diagram follow from them. See it in the demo.

View demo